GSI Tympstar Pro

The NEW GSI TympStar Pro redefines the gold standard set by its predecessor TympStar and takes it to the next level in clinical diagnostic impedance audiometry. The state- of- art TympStar Pro offers an intuitive user interface equipped with the New Tymp Touch Technology™

•    Simultaneous Multicomponent Tympanometry- probe tone frequencies of 226, 678 or 1000 Hz.
•    Resonant  frequency test
•    User Specific Test Protocols: flexibility of pre-defined protocols saves time and creates consistency in testing methodology.
•    Auto Start screening and diagnostic:As soon as a seal is obtained, the sweep begins.
•    Auto Detect Reflex Threshold Seek with Reflex Growth
•    Multiplex pulsed-tone stimuli for reflex:artifact-free acoustic reflex testing and “null” points elimination
•    ESRT- electronic stapedial reflex threshold
•    Eustachian Tube Function: Evaluate Eustachian Tube status with a perforated or intact TM.
•    Intuitive Touch Screen: Equipped with a 12 inch colour display and zoom function
•    Familiar Ergonomic Design:The one-button, one-function design control panel.
•    Shoulder Box Controls: Change ears and start tests directly from the shoulder box.
•    Stores up to 100 tests on instrument
•    Ease of Importing/Exporting Data:Transfer data to GSI Suite for comprehensive and customized reporting.
•    Capability for Direct Printing

GENERAL:
•    Test Types:  Tympanometry, Acoustic Reflex Threshold, Reflex Decay, Eustachian Tube Function (Intact and Perforated)
•    Protocols: Diagnostic, Screening, Multi-component Tympanometry, Auto Sequence and User Defined
•    Probe Tone: 226 Hz (85 dB SPL ± 1.5 dB) 678 Hz (72 dB SPL ± 1.5 dB) 1000 Hz (69 dB SPL ± 1.5 dB) Accuracy: ± 1%
•    Harmonic Distortion: Less than 1%

ADMITTANCE MESASUREMENTS:
•    Range    : 226 Hz (-10 to + 10 mmho)
    678 Hz (-21.0 to +21 mmho)1000 Hz
    (-32.0 to +32 mmho)
•    Sensitivity Scale: Auto Scales to Appropriate Range, Manual selection also possible in Reflex Modes only
PRESSURE MEASUREMENTS:
•    Load volume    : 0.2 to 7.0 ml
•    Range        : Normal = +200 to -400 daPa Wide = +400 to -600 daPa
•    Accuracy    : ± 10% of reading or ± 10 daPa, whichever is greater
•    Sweep Rate    : 12.5, 50.0, 200, 600 and 600/200 daPa/sec.

REFLEX MEASUREMENTS:    
•    Stimuli    : 250, 500, 1k, 2k, 4k, BBN, LBN, HBN, Click, External Input, Non-acoustic

 